DFG50-200A/2/4
Q 12 m³/h · H 40 m · 4 kW
Impeller trim: 177.7 mm · 2026-07-14
Open configuration and sourceUPGR · EAST PUMP
Pumps for building and industrial services.

Pumps by Shanghai East Pump (Group) Co., Ltd. Browse the documented series or start with your duty requirements.
Explore model designations, pump families and two dated factory configuration examples. Prepare an enquiry for the required operating conditions.
Search 1,540 designations and 142 records from the retained pump and packaged-system listing. Choose a designation to prepare an enquiry.
The designation index helps identify a product. Exact hydraulics, materials, electrical configuration, certification, price and availability require confirmation for your duty. Two dated factory selections are available as configuration examples.
The search index loads in your browser. You may also type any designation directly into the enquiry.
Enter flow, head and operating conditions. The program compares Q–H with 17 documented DFG configurations; any match is preliminary.
Basis: 51 printed points at 2900 rpm, DFG / DFW / XA catalogue, PDF page 11 (printed page 08). Values between points use linear interpolation. No calculation is made outside the verified flow span.
Fluid, temperature, installation and electrical supply are not established for these 17 table rows. The program keeps your conditions for supplier verification. This comparison does not confirm a complete factory curve or suitability for the project.
This draft is prepared on your device only. Review it before sending it yourself.
Data from one verified catalogue page; the trimmed diameter is not specified in these rows. Three points do not replace a complete pump characteristic.
| Catalogue designation | Q → H points (m³/h → m) | Motor, kW |
|---|---|---|
| DFG40-200(I)A/2/4 | 8 → 44.7; 11 → 44; 14 → 43 | 4 |
| DFG40-250(I)/2/11 | 8.8 → 81.8; 12.5 → 80; 16.3 → 77.5 | 11 |
| DFG40-250(I)A/2/7.5 | 8 → 71.5; 11 → 70; 14 → 68 | 7.5 |
| DFG40-250(I)B/2/5.5 | 7 → 61.5; 10 → 60; 13 → 56 | 5.5 |
| DFG50-100/2/1.1 | 8.8 → 13.2; 12.5 → 12.5; 16.3 → 11.3 | 1.1 |
| DFG50-100A/2/0.75 | 8 → 10.7; 11 → 10; 14 → 9 | 0.75 |
| DFG50-125/2/1.5 | 8.8 → 21.5; 12.5 → 20; 16.3 → 17.8 | 1.5 |
| DFG50-125A/2/1.1 | 8 → 17; 11 → 16; 14 → 14.3 | 1.1 |
| DFG50-160/2/3 | 8.8 → 33.3; 12.5 → 32; 16.3 → 29.8 | 3 |
| DFG50-160A/2/2.2 | 8 → 29; 11 → 28; 14 → 26.2 | 2.2 |
| DFG50-160B/2/1.5 | 7.1 → 24; 10 → 23; 13 → 20.5 | 1.5 |
| DFG50-200/2/5.5 | 8.8 → 51; 12.5 → 50; 16.3 → 48.5 | 5.5 |
| DFG50-200A/2/4 | 8 → 44.7; 11 → 44; 14 → 43 | 4 |
| DFG50-200B/2/3 | 7.1 → 39; 10 → 38; 13 → 35 | 3 |
| DFG50-250/2/11 | 8.8 → 81.4; 12.5 → 80; 16.3 → 77.5 | 11 |
| DFG50-250A/2/7.5 | 8 → 71.5; 11 → 70; 14 → 68 | 7.5 |
| DFG50-250B/2/5.5 | 7 → 61.5; 10 → 60; 13 → 56 | 5.5 |
Selections dated 2026-07-14 describe specific impeller trims. Their duty points and plots are not merged with the catalogue table above.
Q 12 m³/h · H 40 m · 4 kW
Impeller trim: 177.7 mm · 2026-07-14
Open configuration and sourceQ 46 m³/h · H 40 m · 11 kW
Impeller trim: 173.2 mm · 2026-07-14
Open configuration and sourceCatalogue editions, factory selection reports and document details for EAST PUMP. Each entry explains its scope and the dates stated in the document.
Series catalogues describe the product range and provide data for preliminary selection.
Archived catalogue
64-page catalogue covering three single-stage pump series.
Catalogue performance and dimensions require configuration-specific confirmation.
Archived catalogue
201-page catalogue for WQ submersible sewage pumps.
Archived edition; it does not establish the complete current factory range.
A selection report describes one selected configuration. Its parameters are not the limits of the entire series.
Dated factory selection
Seven-page manufacturer selection report dated 14 July 2026.
One selected configuration; its duty and trim do not apply to every unit in the series.
Dated factory selection
Seven-page manufacturer selection report dated 14 July 2026.
One selected configuration; its duty and trim do not apply to every unit in the series.
Company registration identifies the legal entity. It is separate from the conformity of a particular pump.
Archived copy
An archived copy records Shanghai East Pump (Group) Co., Ltd. under unified social credit code 913100001330789016.
Company-registration evidence. Current corporate status and product conformity are separate checks.
Declarations and attestations identify their own product scope, applicable requirements and dates.
Archived copy
Archived declaration ЕАЭС N RU Д-CN.РА04.В.85588/23 names Shanghai East Pump as manufacturer and includes DFG, DFW, XA and WQ among its series.
Applicability to a selected model and the current registry status require separate verification.
Archived copy
UDEM document M.2023.206.C84865 identifies WQ submersible sewage pumps and references Machinery Directive 2006/42/EC, Annex VIII.
The stated product is WQ. This record does not establish EAEU conformity or cover other pump series. Current issuer status has not been checked.
According to the manufacturer. The following statements describe the company and its product qualification listings; they are separate from the seven document records above.
The manufacturer describes a quality-assurance system based on ISO 9001. The certificate details and current status have not been verified.
The manufacturer lists metrology confirmation and a grade-B pump-inspection/testing assessment among its qualifications. Document details and current status remain unverified.
The company website lists explosion-protection and compulsory-product certification records. The listed titles do not establish coverage or current validity for a selected pump.
The website lists Shanghai technology-centre, high-tech-enterprise and innovation recognitions. These are company claims, separate from product conformity.
The form prepares a draft on this device. Review it and send it yourself through your email app. No request is registered or automatically delivered.
Shanghai East Pump (Group) Co., Ltd.
Model values describe the dated factory selection. A different duty point, impeller trim or motor requires a new check. Series envelopes do not form a pump curve.
Product documents and drawings are reviewed separately for the selected configuration.
DFW Horizontal Single-stage Centrifugal Pumps
XA Single-stage, Single-suction Pumps